Astoria Barista Storm Service and Repair
Recently we carried out a full bench service on a customers Astoria Barista Storm espresso coffee machine. The full details of this off-site bench repair and service can be found in this blog post. If you would like to discuss how we can help you with service and support on your Barista Attitude Storm Espresso Coffee machine. Use our contact page or call us directly on 01904 280052

The Astoria Barista Storm service and repair is complex. With this cutting edge concept designed to allow the operator to precisely control variables within the espresso machine. Producing prefect brewing profiles for each coffee chosen to be used with the machine. Here is a link to the manufactures product page – https://www.barista-attitude.com/products/storm-multiboiler
Lets begin with the customers reported faults; the most basic fault was “no power” the the machine when switched on. As with most cutting edge equipment. The Barista Attitude Storm espresso coffee machine can present a simple fault with a much more complex origin.
Further inspection showed that the steam and water boiler heating element had suffered a rupture. Contaminating the boiler with the element insulation filler. The associated short to earth electrical fault having damaged the contact relay. This resulted in the no power report from the operator.



With such an issue of water circuit souring. The water and steam boiler inevitably had to be removed for cleaning. Whilst the boiler is out of the machine. We also undertook a descaling process to return the boiler to as new condition. The heating element can also be replaced easily whilst the boiler is outside the machine chassis. During the process of removing the heating element. It became apparent the element protection thermostat would also have to be replaced. The sensing vane had become fused with the element assy.




With the 3 Group Astoria Storm machine on the bench we also had the opportunity to address a number of other service faults listed as follows;
-Replacement of heating element protection thermostat.
-Replacement of water faucet solenoid valve.
-Diagnostic inspection and replacement of faulty contact relay.
-Identification and replacement of damaged fuse holder assy.
-Descale treatment and inspection of each group boiler.


Whilst the machine is on the bench, draining, opening and inspection of each group boiler is prudent to reduce any service work in the short term when the machine is returned to site. This inspection showed a small crack on one injector pipe on group two. This injector pipe was exchanged to prevent leaks developing onsite.


The service and repair work is complete so a thorough test is undertaken to confirm the machine is functioning correctly before its return to site.
If you would like to discuss service on your Astoria Barista Attitude Storm or any other espresso machine please contact us using our contact page or call our office on 01904 280052